Справочник Пользователя для INSTEON 2442-522 (aus-nz)

Скачать
Страница из 24
Page 21 of 24  
     
2442-222/2442-422/2442-522 - Rev: 1/21/2014 8:00 AM 
light with another 
controller, the light will 
turn on, then back off 
with an INSTEON on-level at 
a high brightness and an X10 
address on-level at a low 
brightness 
Remove the X10 address from INSTEON 
controller  
When I press a button on 
Micro module, it takes a 
long time for other 
INSTEON devices it is 
controlling to respond 
Micro module is trying to 
control a responder that is not 
responding and may have 
been removed  
Connect power to the responder 
If the INSTEON device is still available, 
remove it from Micro module and then re-add it 
Perform a factory reset  
The load is buzzing when 
on or dim.  
The dimming component 
inside Micro module “chops” 
the power line sine wave to 
reduce the power 
The bulb filaments are vibrating. Use rough-
service, or appliance grade bulbs to reduce the 
noise 
Run Micro module in the “full-on” mode or 
switch to a non-dimming Micro On/Off module 
Micro module is locked up 
A surge or excessive noise 
on the power line occurred  
Power cycle Micro module 
Perform a factory reset 
Micro module is getting 
warm to the touch 
It is normal for dimmers to get 
warm (Micro module 
conforms to safety standards) 
Micro module will dissipate about 1 watt per 
100 watts of load. Using metal junction boxes, 
removing insulation around the outside of the 
box and controlling a smaller load will all help 
lower the temperature. 
Micro module blinks green 
one time after it is 
activated 
Micro module supports an 
error blink feature.  A green 
blink indicates that all 
responders are 
communicating properly 
You may disable error blink via software if 
desired 
Micro module blinks red 
one time after it is 
activated 
Micro module supports an 
error blink to let you know 
that a responder did not 
acknowledge the command 
and that there is a lot of 
unacknowledged 
communications on the 
network 
Confirm that the responder is powered and 
available.  If you don’t want this device to be a 
responder you can unlink it if available or use 
software to remove the link.  Once the issue is 
resolved, you may disable error blink via 
software if desired. 
Micro module can turn off 
my responder, but nothing 
happens when I send an 
on  
Responder’s scene level is 
off 
Add responder to scene again at desired 
scene on-level 
Micro module still controls 
devices even after factory 
reset 
The responder’s link was not 
removed prior to Micro 
module factory reset (called a 
half-link) 
Remove responder from Micro module