NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
5
MINIMUM CLEARANCES TO COMBUS-
TIBLES
Mantel Clearance: Combustible and Non-com-
bustible mantels may be installed at any height 
above the top of the face of fi replace.
Cat. No. H3427
Model: MPE-33R
Description: Merit Plus Electric Fireplace, 
 33” 
Radiant
Shipping Weight: 81 lb.'s (36.75 KG)
Packaging:
 
41” x 17 3/4” x 33 1/2”
 
(1040 mm x 451 mm x 850 mm) 
 
14.1 cu. ft.
Power Requirements: 
 
(120 Volt, 60 Hz.) 
 
 
Rated Wattage - 1600 Watts
 
 
Amperage - 13.33 Amps
 
(240 Volt, 60 Hz.)
 
 
Rated Wattage - 3000 Watts
 
 
Amperage - 12.5 Amps
Blower CFM:  83 CFM
(120 V): 5,461 BTU/HR
(240 V): 10,239 BTU/HR
FIREPLACE SPECIFICATIONS
This appliance is an electric fi replace designed  
to be framed in with combustible materials (up 
to the edge of the appliance). A drywall lip at 
the top of the fi replace and 4 nailing fl anges 
on the sides of the appliance is provided to 
facilitate installation. 
Hearth Protection: A hearth is not mandatory, 
but it is recommended for aesthetic purposes.  
Secure the hearth extension to the fl oor to 
prevent possible shifting. Do no block the air-
fl ow beneath the appliance (read the following 
WARNING).
Clearances
Sides
0 inches - 0 mm
Floor
0 inches - 0 mm
Top
0 inches - 0 mm
Table 2
       WARNING 
Electrical wiring must comply 
with local building codes and 
other applicable regulations to 
reduce the risk of fi re, electrical 
shock and injury to individuals.
       IMPORTANT 
Any electrical re-wiring of this 
appliance must be done by a 
qualifi ed electrician.
       WARNING 
Do not use this fi replace if any 
part of it has been underwater.  
Immediately call a qualified 
service technician to inspect the 
fi replace and replace any part of 
the electrical system which has 
been under water.
3.  Wire a dedicated, properly fused circuit with 
an Amp rating for the appropriate voltage 
(120 V - 15 Amps or 240 V - 20 Amps). 
A dedicated circuit is required to prevent 
overloading a house circuit in cases of having 
multiple appliances on the same circuit.  
Use an outlet that is protected by a ground 
fault circuit interrupter where required by 
electrical code. 
4.  (If applicable) Make wall mount wall switch 
or wall thermostat connections as outlined 
on Pages 11 & 12.
5.  Perform a function test. See Manual Control 
Panel Operation on Page 6 and Remote 
Control Operation 
on Page 7.
ELECTRICAL CONNECTIONS
Refer to the electrical diagrams on Pages 10 
to 14.
PRE-INSTALLATION
Before You Start
Check appliance for any concealed damage.
DETAILED INSTALLATION STEPS
1. Complete the framing opening to the dimen-
sions specifi ed in Figure 2
2. Prepare the connections to power source:
  120 Volt Connections - Locate the power 
cord on the left side of the unit and connect 
it to the outlet installed during the framing 
(see Figure 2).  Verify that the power to the 
receptacle is off.
  Hard wired installation:
  Ensure that there is a minimum of 8" of the 
service cable for connection to the junction 
box on the fi replace.
  -  Loosen four screws to remove the junction 
box cover plate.
  -  Disconnect and remove the 120 Volt power 
cord from the fi replace wires.
  - Position the fi replace into the framed-in 
opening.  Attach fi replace to frame using 
nailing fl anges provided.
  - Complete the wiring to the fi replace as 
shown on Page 10.
  -   Place all wire connectors inside the junction 
box.
  - Attach junction box cover plate with four 
screws.
   240 Volt Connections - Ensure that there 
is a minimum of 8" of the service cable 
for connection to the junction box on the 
fi replace.
  -  Loosen four screws to remove the junction 
box cover plate.
  -  Disconnect and remove the 120 Volt power 
cord from the fi replace wires.
  - Position the fi replace into the framed-in 
opening.  Attach fi replace to frame using 
nailing fl anges provided.
  - Complete the wiring to the fi replace as 
shown on Page 11.
  -   Place all wire connectors inside the junction 
box.
  - Attach junction box cover plate with four 
screws.
    The fi replace wires L1, L2, N, N1, N2 and 
G are attached to the rear of the junction 
box cable clamp for easy access.