CHAPTER 10   A/D CONVERTER
Figure 10-2.  A/D Converter Mode Register Format
Notes 1. Set so that the A/D conversion time is 19.1 
µ
s or more.
2. Setting prohibited because A/D conversion time is less than 19.1 
µ
s.
Cautions 1. The following sequence is recommended for power consumption reduction of A/D
converter when the standby function is used: Clear bit 7 (CS) to 0 first to stop the
A/D conversion operation, and then execute the HALT or STOP instruction.
2. When restarting the stopped A/D conversion operation, start the A/D conversion
operation after clearing the interrupt request flag (ADIF) to 0.
Remarks 1. f
X
: Main system clock oscillation frequency
2. MCS : Oscillation mode selection register (OSMS) bit 0
CS
7
TRG
6
FR1
FR0
4
ADM3
3
2
1
0
FF80H
Address
ADM
Symbol
ADM2 ADM1 HSC
5
01H
After 
Reset
R/W
R/W
ADM3
0
0
0
0
1
1
1
1
ADM2
0
0
1
1
0
0
1
1
ADM1
0
1
0
1
0
1
0
1
Analog Input Channel Selection
ANI0
ANI1
ANI2
ANI3
ANI4
ANI5
ANI6
ANI7
TRG
0
1
External Trigger Selection
No external trigger (software starts)
Conversion started by external trigger (hardware starts)
FR1
0
0
1
1
FR0
0
1
0
0
Other than above
A/D Conversion Time Selection
Note 1
f
X
=5.0 MHz Operation
MCS=1
80/f
X
 (Setting prohibited
Note 2
)
40/f
X
 (Setting prohibited
Note 2
)
50/f
X
 (Setting prohibited
Note 2
)
100/f
X
 (20.0   s)
Setting prohibited
µ
MCS=0
160/f
X
 (32.0   s)
80/f
X
 (Setting prohibited
Note 2
)
100/f
X
 (20.0   s)
200/f
X
 (40.0   s)
f
X
=4.19 MHz Operation
MCS=1
80/f
X
 (19.1   s)
40/f
X
 (Setting prohibited
Note 2
)
50/f
X
 (Setting prohibited
Note 2
)
100/f
X
 (23.8   s)
MCS=0
160/f
X
 (38.1   s)
80/f
X
   (19.1   s)
100/f
X
 (23.8   s)
200/f
X
 (47.7   s)
µ
µ
µ
µ
µ
µ
µ
CS
0
1
A/D Conversion Operation Control
Operation stop
Operation start
HSC
1
1
0
1
µ
µ