Do not obstruct the flow of combustion and ventilation air. Adequate clearance for air openings into the
combustion chamber must be provided. Make sure there is an adequate supply of air in the room to
replace air taken out by the ventilating system.  Do not permit fans to blow directly at the broiler. Avoid
wall-type fans which create air cross currents within the room.  Avoid open windows next to the broiler.
INSTALLATION CODES AND STANDARDS
The broiler must be installed in accordance with:
In the United States of America:
1. State and local codes.
2. National Fuel Gas Code, ANSI-Z223.1 (latest edition). Copies may be obtained from The
American Gas Association, Inc., 1515 Wilson Blvd., Arlington, VA 22209.
In Canada:
1. Local codes.
2. CAN/CGA-B149.1  Natural Gas Installation Code (latest edition).
3. CAN/CGA-B149.2  Propane Installation Code (latest edition), available from The Canadian Gas
Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3.
LEVELING
Place a carpenter's level inside the broiler. Level the broiler front to back and side to side.  Unless the
broiler is level, it will not give proper cooking results.
GAS CONNECTIONS
CAUTION:  Gas supply connections and any pipe joint compound must be resistant to the action
of propane gases.
Location of the gas inlet is on the lower rear right corner of the broiler. Codes require that a gas shutoff
valve must be installed in the gas line ahead of the broiler.
Connect gas supply to the broiler. Make sure the pipes are clean and free of obstructions.
Connection of Manifolds in a Battery:  Two or more broilers can be coupled together at the manifold
by removing the front control panel to make necessary connections.  Be sure to cap open ends.  To
connect, adjust manifold by loosening U-bolts.  In a large battery of eight or more units, the gas should
be fed from both ends of the battery.  T gas connections can be installed whenever necessary for
increased gas supply.
For further details, consult your local gas company.