1.  Pull wires through wire 
hole. Position coverplate 
on wall, level and mark hole 
positions.
2.  Drill holes (3/16” for drywall, 
7/32” for plaster) and tap in 
supplied wall anchors.
3.  Pull wire through coverplate 
and subbase, position over 
anchors, then insert and 
tighten mounting screws. 
Check level if desired.
4.  Apply the large-print labels 
to the coverplate, matching 
the labels on the subbase.
1.  Loosen screw terminals, insert wires 
into terminal block, then re-tighten 
screws.
2.  Push excess wire back into the wall 
opening. 
3.  Plug the wall opening with 
nonflammable insulation to prevent 
drafts from affecting thermostat 
operation.
Terminal Designations
Heat relay.
Compressor contactor.
Fan relay.
Heat pump changeover valve 
energized in cooling.
Rc  Cooling power. Connect to 
secondary side of cooling system 
transformer.
Heating power. Connect to 
secondary side of heating system 
transformer.
Heat pump changeover valve 
energized in heating.
Wiring
NOTES
R & Rc terminals
In single-transformer system, leave metal 
jumper in place between 
R
 & 
Rc
. Remove 
metal jumper if two-transformer system.
Heat pump systems
If wiring to a heat pump, use a small piece 
of wire (not supplied) to connect terminals 
and Y.
Wire specifications
Use 18- to 22-gauge thermostat wire. 
Shielded cable is not required.
R
G
W
Y
B
Rc
O
E
F
Coverplate
Subbase
Large-print 
subbase switch 
labels
Subbase and base installation