Locate  the (2) 1m H chokes going from  the rear-m ost tube  socket p in.  Remove each of
these chokes.  Clean out the hole through which the chokes were removed.
( )
In place of these chokes, install a 27
Ω
 resistor paralleled with one 820pF disc capacitor (1
resistor/ca pacitor pair for each choke).
( )
On the  right hand tube socket, parallel the existing 200pF capacitor closest to the front
panel with (1) 820pF disc capacitor.  Leave all other 200pF capacitors in place.
( )
On the left hand tube socket, parallel the 200pF c apacitor on the extrem e left with the
remaining 820pF disc capacitor.  Leave all other 200pF capacitors in place.
( )
Locate  the 2-lug terminal strip just behind the filament choke (the input drive coax is
connected here).  Remove the capacitor going from this strip to the filament wires.  Clean
solder from  the terminal strip w here you just rem oved the capacitor.
( )
Install 1 lead of each of the 0.01
µ
F 1KV disc capacitors through the terminal you just
cleaned.  Have the body of the capacitors ab out 3/8” from  the terminal with the c apac itors
lying flat and pointing to the left.
( )
Take  (1) 10
Ω
 2W  resistor and wrap a lead around the closest filament jumper conne ction
(the one going between the tube sockets).  Place the body of the resistor about 3/8” from
the filament jumper lead.  Solder and trim any excess lead.
( )
Connect  the free end of this resistor to the undermost 0.01
µ
F 1KV capac itor lead.  Twist
these leads together and solder.  Trim any excess leads.
( )
In a like manner, install the second 10
Ω
 2W  resistor onto the other filament jumper lead,
spacing th e bod y about 3/8” from  the jum per.
( )
Connect the free lead of this resistor to the upperm ost 0.01 mF 1KV c apacitor lead.  Twist
these leads together and solder.  Trim any excess leads.
( )
Space all components so that there is at least 1/8” between any 2 wires or components.
Sight across the bottom  of the amplifier to be sure that there is plenty of clearance between
the components you just installed and where the case will soon fit.  Adjust as needed.
( )
Replace the perforated cover and top rear plate cov er.  Reinstall the 15 s heet m etal screws
holding these p ieces in place.  DO NOT over tighten these screws, as it is fa irly easy to
strip the screw threads in the aluminum underneath.
( )
Use the  book to hold the am plifier while you reinstall the case and feet..
This completes the installation of the PS-220 Parasitic Suppressor kit.  You will find that
your amplifier tunes much  m o re   sm oothly than before and there will be no more arcing or spitting
on voice peaks.