Outdoor Unit
Test conditions
1.  Cooling: Indoor Dry Bulb Temp. (°C) 27  
Outdoor  Dry Bulb Temp. (°C) 35
 
  Wet Bulb Temp. (°C) 19  
 
Wet  Bulb Temp. (°C) 24
Heating: Indoor Dry Bulb Temp. (°C) 20  
Outdoor  Dry Bulb Temp. (°C) 7
 
  Wet Bulb Temp. (°C) 12 (MAX)   
Wet Bulb Temp. (°C) 6
2. Standard piping length: 7.5m (Includes Indoor Unit piping length).
 
 
 Model
 
 
 CS-RE9JKX
         CU-RE9JKX
 
 
 CS-RE12JKX
         CU-RE12JKX
 
 
 CS-RE15JKX
         CU-RE15JKX
COOL
HEAT
COOL
HEAT
COOL
HEAT
Single, 230V, 50Hz Single, 230V, 50Hz
Single, 230V, 50Hz
 
 Power/Current
[kW]
0.700
0.820
1.010
1.120
1.260
1.540
[A]
3.45
3.70
4.70
5.20
6.05
7.10
 
  Refrigerant
[kg]
R410A
0.810
R410A
0.970
R410A
0.970
  Cooling Capacity
[kW]
2.500
3.500
4.200
 
 Heating Capacity
[kW]
3.300
4.250
5.300
Noise Level
JIS C 9612 
[<70 dB(A)]
[dB(A)]
   
42
42
42
42
46
47
Conditions 
1m Distance 
Max. cooling/
heating 
operation
47
48
48
50
50
51
Sound power 
level
[dB(A)]
   
53
53
53
53
57
58
60
61
61
63
63
64
 
 Air Circulation
[m
3
/min.]
13.8
13.8
13.8
14.5
14.4
15.3
 
 Product Weight
[kg]
   
9.0
9.0
9.0
28
30
36
 
 Dimensions (L x W x H)
[mm]
   
848 × 204 × 290
780 × 289 × 540
kg
  
PRODUCT SPECIFICATION