Руководство По Работе для Panasonic KYT935XLEPG

Скачать
Страница из 160
EN-
45
English
Electrical Work
WARNING
Electrical work must be performed by a legally qualified electrician.
Electrical Requirements
Installation of the Earth Leakage Circuit Breaker
 
■ This appliance must be supplied with the proper voltage and frequency, and 
connected to an individual, properly earthed branch circuit, protected by a 
circuit breaker or fuse. (The rating plate is on the bottom of the appliance.)
 
■ This appliance is not fitted with other means for disconnection from the supply 
mains having a contact separation in all poles that provide full disconnection 
under overvoltage category III conditions. Means for disconnection must be 
incorporated in the fixed wiring in accordance with the wiring rules.
 
■ Single-phase A.C. 220-240 V, 50 Hz electrical system must be used. (It is also 
possible to use a three-phase electrical system.) If connecting to aluminium 
wiring, use connectors approved for use with aluminium wiring.
 
■ Check with the local utilities for electrical codes applied in the area. Failure to 
wire the appliance according to governing codes may result in a hazardous 
condition. 
 
■ After installation, show the customer where the breaker for the appliance is 
located.
 
■ In accordance with the electrical wiring rules, incorporate the earth leakage 
circuit breaker in the home electrical wire.
 
■ Follow the specification of the earth leakage circuit breaker as follows. 
Rated current: 50 A*, rated sensitivity current: 30 mA 
*  If rated current is 40 A, please change to 7200 W under “Power Management” 
in settings. (See page 11)