Page 7 of 13
NM-2V
Two voice/fax interface card slot network module
Cisco IOS Requirement
11.3(1)T or later for Cisco 3600
11.3(4)T or later for Cisco 2600
12.2(8)T or later for Cisco 2691, 2600XM, and 3700
Cisco Part Number
800-02491-01
FCC Specifications
FCC Class B device
Spare
NM-2V=
MTBF
755,717 hours
Requires at Least One VIC (maximum
of two)
VIC-2FXS 800-02493-01
VIC-2FXO 800-02495-01
VIC-2E/M 800-02497-01
VIC-2FXO-EU 800-03639-01
VIC-2FXO-M1 800-05298-01
VIC-2FXO-M2 800-05920-01
VIC-2FXO-M3 800-04581-01
VIC-2BRI-S/T-TE 800-03803-1
VIC-2BRI-NT/TE 800-07272-01
VIC-2DID 800-06487-01
VIC-2CAMA 800-18443-01
VIC-2FXS
Two-port FXS voice/fax interface card
Interface Type
Foreign exchange station
Cisco IOS Requirement
11.3(1)T or later for Cisco 3600
11.3(4)T or later for Cisco 2600
12.2(8)T or later for Cisco 2691, 2600XM,and 3700
Cisco Part Number
800-02493-01
Compliance
FCC Class B device, CE
Safety Conformance
UL1950
Spare
VIC-2FXS=
Address Signaling Formats
In-band DTMF
Out-of-band pulse (10/20 pps)
Signaling Formats
Loop start, ground start
Ringing Tone
Configurable for different country requirements
Ringing Voltage
<45 Vrms at 5 REN at 25 Hz (configurable frequency)
Ringing Frequencies
20 Hz, 50 Hz
Physical Connector
RJ-11
Number of Connectors/Ports
Two
MTBF