Инструкции Пользователя для Wet Sounds SD6

Скачать
Страница из 10
14
SINISTER SPECIFICATIONS
15
The Sinister amplifiers are equipped with an advanced microprocessor 
controlled diagnostic system. This system is designed to notify you in the 
event the amplifier goes into protection for any reason. With a series of 
LED codes, the amplifier will indicate the status to help in troubleshooting.
Short protect and DC output protection: 
 LED flashes for .25 seconds and 
off for .25 seconds repeatedly.                                             
Low Battery Voltage: 
 LED flashes for 1 second and then off for .25 seconds.                         
High Battery Voltage: 
 LED flashes for .25 second and then off for 1 second.                          
Thermal Rollback Notification: 
 
 
Amp is limited to low power:
  LED flashes for .25 seconds and then  
  
off for 3 seconds
 
Amp is limited to medium power:
  LED ON  for 3 seconds and then   
  
off for 3 seconds 
 
Amp is limited to medium-high power:
  LED ON  for 3 seconds     
 
and then off for .25 seconds                                                                    
SINISTER MICRO PROCESSOR DIAGNOSTIC SYSTEM
M. Input Source Selection
 - When on ch 1-2 the channel 5-6 outputs are  
    active from channels 1-2 input.  Eliminating the need for external y  
    adapters. This is useful if you are using one amp to power all speakers  
    in the same zone and do not need any type of fading ability or need  
    separate control from an EQ.  When on ch 5-6, you will need a RCA  
    cable direct into the 5-6 RCA input to activate the 5-6 outputs.
N. Variable Crossover 5-6 
 - Built in 12db filter with crossover frequencies  
    between 30Hz – 290Hz
O. Crossover Selection Switch 5-6 
 - The HIGH pass attenuates low  
    frequencies and is used with mid-range speakers and tweeters. LOW  
    Pass attenuates high frequencies and is used for subwoofers. Full does  
    not attenuate any frequencies and is for full range speaker systems. 
P. Gain Control 5-6 
 - This is the input sensitivity gain control for channels  
    5 & 6. E-Mono-Stereo Selection switch.  Stereo is used in applications  
    where stereo is needed and bridge outputs are not used.  Mono is used  
    when bridging mono for a subwoofer for example.  Both the left and  
    right channels are combined into a mono signal that is sent to both  
    outputs giving you a true mono output.
Q. Mono-Stereo Selection Switch 
- Stereo is used in applications where  
    stereo is needed and bridge outputs are not used.  Mono is used when  
    bridging mono for a subwoofer for example.  Both the left and right  
    channels are combined into a mono signal that is sent to both outputs  
    giving you a true mono output.
SINISTER SERIES CONTROLS CONT.
SD6 Class D Control Cont.
Channel 5-6
13.500
2.7
9.819