4-16
SAL500F80 (REFLEX 8/500) (500mm F8 Reflex)
9)
Turn the helicoids unit to the closest distance side (fully to the measurable range flange back tester).
Check that the red and green color shifts at right and left are even.
10) Apply the adhesive bond (B-10) in the width of 30mm to two indicated locations of G1 stopper (Refer to HELP 12)
11) Screw the G1 stopper into the helicoid unit until its tip touches the inner part (G1+G3+G7 assy).
And then tighten further the G1 stopper about 5 to 10mm.
Note:
After tightening, confirm that the lens inside the helicoid unit does not rattle when the helicoid unit is shaken.
Do not tighten the G1 stopper too strongly.
12) After adjustment, apply the adhesive bond (B-10) to two indicated holes of G2 stopper and attach it to the helicoids unit.
13) After adjustment, apply the adhesive bond (B-10) to the tip of the G1 adjustment screws (three areas).
Fig.4-2-7
Apply the Adhesive Bond (B-10)
Helicoid Unit
Apply the Adhesive Bond (B-10)
to Fix G2 Retainer (Two areas)