Справочник Пользователя для Autel Intelligent Tech. Corp. Ltd. MAXISYSMS906BT

Скачать
Страница из 151
Oscilloscope Operations   
 
  Screen Layout and Operations 
127 
 
line up and down to move and view different areas of the scale. 
4. 
Tap  once  on  the  screen  area  outside  of  the  Y-axis  to  finish  the 
voltage scale adjustment. 
 
To adjust the time base scale 
1. 
Unselect the Y-axis if it
’s activated. 
2. 
Use  your  2  fingers  to  adjust  the  time  base  with  the  typical  zoom 
gestures on the measurement grid area. 
16.4.4 Measurement Rulers 
The Measurement Rulers allow the voltage and time duration of a waveform to 
be measured precisely. There are 2 kinds of measurement rulers: the vertical 
Time Ruler and the horizontal Voltage Ruler
Tap  on the 
Ruler  Activator  on  the  bottom right  corner  of the  measurement 
grid  and  drag  it  across  the  screen  to  the  desired  position,  a 
Time  Ruler  is 
generated. 
The 
Voltage Ruler can be generated in the similar way by clicking the Ruler 
Activator on the top left corner and dragging it downwards. 
When 
Measurement Rulers are generated, a Ruler Table showing time and 
voltage  values  for  the  corresponding  channels  will  be  displayed.  The 
Delta 
icon refers to the absolute difference between the values of the 2 rulers, which 
can be locked by tapping the 
Lock icon.