Grounding when using IDU-LA  
Antenna must be placed on the mast on the level that is at least 1 meter lower 
than a mast‘s top. In this case it is of big probability that the lightning strikes the 
mast and not the antenna. The mast is to be grounded on the grounding contour 
according  to  your  local  standards.  When  the  lightning  strikes  the  antenna,  the 
current goes through the coaxial  cable which grounds ODU clamp with the mast 
– the mast is grounded via the grounding contour. The direct lightning strike to 
the  STP  service  cable  (ODU-IDU)  is  partially  terminated  on  the  grounded  IDU 
case.  Partial  termination  means  that  the  direct  lightning  strike  will  probably 
destroy  an  STP  cable.  The  service  cable  pickups  from  the  electromagnetic 
impulses are terminated on the IDU case by the winding shield, and further – on 
the grounding contour.  
 
 
The end of the STP service cable that is connected to IDU should be 
assembled with a Shielded RJ-45 connector. The other end of the STP 
service  cable  (connected  to  ODU)  should  be  assembled  with 
unshielded (standard) RJ-45 connector. 
 
The  data  &  power  wires  pickups  are  terminated  via  IDU  protection  scheme 
(discharger  and  additional  air  gap).  ODU  and  IDU  grounding  contours  are 
connected  with  100kOhm  resistor,  and  that  provides  no  static  charge 
accumulation on the ODU case if there are some problems with its connection to 
the grounding contour. 
 
 
Antenna pole, tower, ODU and  lightning  arrestor  must  be connected 
to the first common grounding contour. Cable thickness  must be not 
less  than  10AWG  using  corrosion-steady  connectors.  Grounding 
contour development must be done by the skilled personnel.  
 
A special attention should be paid if antenna used is not DC-shorted. In this case 
additional  lightning  arrestor  should  be  used  between  the  antenna  and  ODU. 
Suggested grounding diagram is shown on the picture below.