3. InfiNet Wireless R5000-L/Lm  
Installation guidelines 
1.  Unpack the equipment 
2.  Check items integrity 
3.  Prepare  RF-cables  of  the 
required  length.  For  5GHz 
devices  the  recommended 
maximal  RF  cable  length  is 
1 meter. 
4.  Install  and  isolate  the 
connectors on the RF cable 
5.  Determine  the  STP  cable 
length  that  is  used  to 
connect  IDU  and  ODU.  The 
total  cable  length  between 
LAN (behind IDU) and ODU should not be longer than 100 meters.  Service 
cable connecting IDU and ODU should be  STP Cat 5E cable. 
6.  Install (solder) connector for ODU side on the STP cable and isolate it 
7.  Lay the STP cable ―from top to bottom‖ – from ODU to IDU 
8.  After  the STP  cable has been  laid, use distribution box to switch  from  STP 
cable to UTP cable with RJ-45 connectors. 
9.  Install ODU on the mounting bracket connectors down and tighten it 
10.  Connect the ODU-IDU cable to the ODU 
11.  Isolate the ODU connector joint place 
12.  Once the antenna and antenna pole are 
installed  they  must  be  grounded  via 
lightning  protection  grounding  contour. 
Antenna‘s  position  must  be  lower  than 
the  highest  antenna  pole  point  at  least 
by 2 antenna heights. If antenna is NOT 
DC-shorted  (see  antenna  technical 
documentation), the additional lightning 
arrestor  must  be  used  which  is  placed 
between  ODU  and  antenna  and  is 
grounded to the antenna pole grounding 
contour. 
13.  Connect RF cable to the antenna. Twist 
the connector tightly 
14.  Connect RF cable to the ODU previously 
having touched RF cable connector case 
with ODU connector case 
15.  Isolate  RF  connectors  from  both  sides 
(ODU and antenna) 
16.  Connect the UTP cable to IDU 
17.  Provide grounding for IDU 
18.  Connect Ethernet cable to IDU 
19.  Provide power supply for IDU