5 Alarms 
 
  
  Page 
41
 
5.5  EXTERNAL ALARM INPUTS AND OUTPUTS 
 
G1038Z0
 
G1038Z0
 
figure 5-2 Flange connector, 5 poles 
figure 5-3 Flange connector, 7 poles 
 
 
The alarm outputs (open collector output 5 V / 1 mA) are normally low. In case of an 
alarm they are high active (5 V). They can be used to monitor alarms with an external 
alarm indicator. 
 
The +28 V pin (for its location see figure 5-3 Flange connector, 7 poles) is protected 
by a 500 mA thermoswitch. In case of exceeding this current between pin 7 and GND 
and/or in case of a failure of the VSWR module, the thermoswitch turns into a high-
resistive status. Then no fuse needs to be replaced. Just wait a few minutes until the 
thermoswitch reaches the normal operating temperature again. 
 
)
 Note: 
The manufacturer / supplier of this system accepts no liability for 
damage caused by equipment connected to external outputs or by 
effects from such equipment.