2.5. Block Diagram Tab 
 
A block diagram of the circuit is presented to give a convenient possibility to change 
registers and modify properties of circuit blocks by clicking the X  button in the lower 
right corner of some blocks. A new dialog box is opened where you can modify values of 
registers by entering new values in the text entry controls or selecting appropriate values 
from selection controls. 
All values shown in the controls are read from AS3990 registers when the dialog box is 
opened. Writing to the registers is executed upon clicking the OK button. You will be not 
asked for confirmation. There is no undo. Some combinations of register values can 
severely degrade operation of the Reader. You can restore default values in Registers tab 
clicking Set Defaults button. 
 
The Block Diagram tab enables modification of majority of registers. All register values 
maybe modified in the Registers Tab.