Листовка для Intermec IF61 IF61B10111000002
Модели
IF61B10111000002
North America
Corporate Headquarters
6001 36th Avenue West
Everett, Washington 98203
Phone: (425) 348-2600
Fax: (425) 355-9551
6001 36th Avenue West
Everett, Washington 98203
Phone: (425) 348-2600
Fax: (425) 355-9551
South America & Mexico
Headquarters Office
Newport Beach, California
Phone: (949) 955-0785
Fax: (949) 756-8782
Newport Beach, California
Phone: (949) 955-0785
Fax: (949) 756-8782
Europe/Middle East &
Africa Headquarters Office
Reading, United Kingdom
Phone: +44 118 923 0800
Fax: +44 118 923 0801
Reading, United Kingdom
Phone: +44 118 923 0800
Fax: +44 118 923 0801
Asia Pacific
Headquarters Office
Singapore
Phone: +65 6303 2100
Fax: +65 6303 2199
Headquarters Office
Singapore
Phone: +65 6303 2100
Fax: +65 6303 2199
Internet
www.intermec.com
Worldwide Locations:
www.intermec.com/locations
www.intermec.com
Worldwide Locations:
www.intermec.com/locations
Sales
Toll Free NA: (800) 934-3163
Toll in NA : (425) 348-2726
Freephone ROW: 00 800 4488 8844
Toll ROW : +44 134 435 0296
Toll Free NA: (800) 934-3163
Toll in NA : (425) 348-2726
Freephone ROW: 00 800 4488 8844
Toll ROW : +44 134 435 0296
OEM Sales
Phone: (425) 348-2762
Phone: (425) 348-2762
Media Sales
Phone: (513) 874-5882
Phone: (513) 874-5882
Customer Service and Support
Toll Free NA: (800) 755-5505
Toll in NA : (425) 356-1799
Toll Free NA: (800) 755-5505
Toll in NA : (425) 356-1799
Copyright © 2009 Intermec Technologies Corporation. All
rights reserved. Intermec is a registered trademark of Intermec
Technologies Corporation. All other trademarks are the
property of their respective owners. Printed in the U.S.A.
611819-01B 01/09
rights reserved. Intermec is a registered trademark of Intermec
Technologies Corporation. All other trademarks are the
property of their respective owners. Printed in the U.S.A.
611819-01B 01/09
In a continuing effort to improve our products, Intermec
Technologies Corporation reserves the right to change
specifications and features without prior notice.
Technologies Corporation reserves the right to change
specifications and features without prior notice.
The IF61 Enterprise Reader is based
on Intermec’s IM5 radio module,
which is EPCglobal Certified
Compliant and Interoperable.
Physical Description
The IF61 enterprise reader incorporates the Intermec
IM5 radio module as well as an Intel Celeron M
600 MHz processor and up to 1 GB of optional
memory. The IF61 can host applications written
in Java, JavaScript, VB .Net or C# .Net, while also
monitoring external sensors and controlling audible
and visual indicators. The IF61 meets ETSI and FCC
standards and is factory configured to operate in
many regions including USA and Canada, EU, China,
S. Korea, Thailand, Australia, and New Zealand.
IM5 radio module as well as an Intel Celeron M
600 MHz processor and up to 1 GB of optional
memory. The IF61 can host applications written
in Java, JavaScript, VB .Net or C# .Net, while also
monitoring external sensors and controlling audible
and visual indicators. The IF61 meets ETSI and FCC
standards and is factory configured to operate in
many regions including USA and Canada, EU, China,
S. Korea, Thailand, Australia, and New Zealand.
Physical Characteristics
Length: 32.4 cm (12.74 in)
Width: 22.6 cm (8.90 in)
Height: 10.8 cm (4.25 in)
Weight: 2.55 kg (5.62 lbs)
Environment
Operating Temperature: -25°C to 55°C (-13° F to 131° F)
Storage Temperature: -30ºC to 75ºC (-22° F to 167° F)
Humidity: 10% to 90% (Non-condensing)
Enclosure: IP54
Shock and Vibration: MIL-PRF-28800F, Class 2
Standard Features
Intel Celeron M 600 MHz processor
Communications Interface options:
Ethernet and optional Wi-Fi
Configuration: Internal web Graphical User Interface (GUI)
General Purpose Input/Output (GPIO)
Four mono-static RF ports
Dense Reader Mode
Built-in power supply
Communications Interface options:
Ethernet and optional Wi-Fi
Configuration: Internal web Graphical User Interface (GUI)
General Purpose Input/Output (GPIO)
Four mono-static RF ports
Dense Reader Mode
Built-in power supply
RF Antenna Connections
Four mono-static RF ports: FCC -Reverse
SMA. ETSI Standard SMA, 30 dBm to 10 dBm
RF power output software controlled
SMA. ETSI Standard SMA, 30 dBm to 10 dBm
RF power output software controlled
RFID Frequency Ranges
865, 869, 915 and 950 MHz
Tag Air Interfaces
EPCglobal UHF Gen 2
ISO 18000-6b
ISO 18000-6c
Philips Version 1.19
Fairchild G1
ISO 18000-6b
ISO 18000-6c
Philips Version 1.19
Fairchild G1
Host Interface Protocols
Intermec Basic Reader Interface (BRI),
EPCglobal ALE and LLRP
EPCglobal ALE and LLRP
Power
Internal power supply: 95-264 VAC auto ranging,
47-63 Hz
47-63 Hz
GPIO
A 25 pin D-Type connector provides the GPIO interface
4 optically isolated inputs (0-40 VDC).
4 optically isolated outputs (0-48 VDC).
Supply output 12 VDC at 500 mA.
4 optically isolated inputs (0-40 VDC).
4 optically isolated outputs (0-48 VDC).
Supply output 12 VDC at 500 mA.
Processor
Intel Celeron M 600 MHz
Memory
128 MB of DDR expandable to 1 GB
1 GB Flash memory standard
Optional 40 GB hard drive
1 GB Flash memory standard
Optional 40 GB hard drive
Connectivity
Ethernet: IPv4 & IPv6, Auto detect and
selectable 10-100 Mbps full and half duplex
Optional 802.11 a/b/g Wi-Fi
USB for storage
RS-232 for peripheral devices
selectable 10-100 Mbps full and half duplex
Optional 802.11 a/b/g Wi-Fi
USB for storage
RS-232 for peripheral devices
Indicators LEDs
Power; Intermec Ready-to-work; Ethernet; Wi-Fi;
RF power; Tag Identification
RF power; Tag Identification
Network Services
HTTP/HTTPS Web server, SSH server, FTP server,
Telnet server, Domain Name System (DNS), Simple
Network Time Protocol (SNTP), Syslog, Server Message
Block (SMB/CIFS),Network File System (NFS)
Telnet server, Domain Name System (DNS), Simple
Network Time Protocol (SNTP), Syslog, Server Message
Block (SMB/CIFS),Network File System (NFS)
Device Management
Wavelink Avalanche Client
Intermec SmartSystems
SNMP v1-3
Intermec SmartSystems
SNMP v1-3
Device Discovery
Bonjour® UDP discovery Service
UPnP® Discovery
DHCP
Intermec SmartSystems
UPnP® Discovery
DHCP
Intermec SmartSystems
Device Configuration
Options for RF configuration, tag types, tag
reporting, tag singulation, medium access,
antenna configurations, and more via:
• HTTP/HTTPS
• RS-232
• Intermec SmartSystems
• Wavelink Avalanche™ Client
reporting, tag singulation, medium access,
antenna configurations, and more via:
• HTTP/HTTPS
• RS-232
• Intermec SmartSystems
• Wavelink Avalanche™ Client
Firmware Upgrades
Web interface using HTTP/HTTPS
Intermec SmartSystems
USB
Wavelink Avalanche™ Client
Intermec SmartSystems
USB
Wavelink Avalanche™ Client
Security
Username & password
Enable/Disable network services
RADIUS client
Enable/Disable serial configuration
Server and CA Certificates
OpenSSL
SSH
Enable/Disable network services
RADIUS client
Enable/Disable serial configuration
Server and CA Certificates
OpenSSL
SSH
Enterprise Software Support
EPCglobal Application Level Events
(ALE) 1.1 implementation
EPCglobal Low Level Reader Protocol
(LLRP) implementation
SAP Auto-ID Infrastructure (AII)
Device Controller certified
IBM Ready4 Platform certified supporting
IBM Premises Server 6.1
Microsoft BizTalk RFID Provider implementation
(ALE) 1.1 implementation
EPCglobal Low Level Reader Protocol
(LLRP) implementation
SAP Auto-ID Infrastructure (AII)
Device Controller certified
IBM Ready4 Platform certified supporting
IBM Premises Server 6.1
Microsoft BizTalk RFID Provider implementation
Development Environments
Built in Java Virtual Machine: JSE v6.0
VB Net & C# .Net support
OSGi console
JavaScript Interpreter
Built-in JavaScript workbench
Built-in application installer
Equinox OSGi Framework
Web test interfaces: Display tags, GPIO test, BRI commands
Intermec Development Libraries for Java and .Net
VB Net & C# .Net support
OSGi console
JavaScript Interpreter
Built-in JavaScript workbench
Built-in application installer
Equinox OSGi Framework
Web test interfaces: Display tags, GPIO test, BRI commands
Intermec Development Libraries for Java and .Net
Accessories
802.11 a/b/g radio, power cables, antennas, antenna
cables, mounting bracket, internal hard drive
cables, mounting bracket, internal hard drive
Standards
AIAG B-11
ANS INCITS 256:1999 (R2001) - Parts 2, 3.1 & 4.2
ANSI MH10.8.4
ISO/IEC CD18000 Part 4
ISO/IEC WD18000 Part 6
ANS INCITS 256:1999 (R2001) - Parts 2, 3.1 & 4.2
ANSI MH10.8.4
ISO/IEC CD18000 Part 4
ISO/IEC WD18000 Part 6
Restrictions on Use
Some approvals and features may vary by country and
may change without notice. Please check with your
local Intermec sales office for further information.
may change without notice. Please check with your
local Intermec sales office for further information.