CAUTION: Installation of the module cannot modify or disturb the vinyl jacket on the hose
nozzle.
NOTICE:
Healy 400 and 900 series nozzles are NOT permitted to have the hose modules mounted
on the left side as it may interfere with the operation. Side mounting is only allowed on the right side
as shown above
as shown above
.
2. The installer must also verify that the hose module does not interfere with dispenser or nozzle
operation. After mounting the hose module place the nozzle back on the dispenser holster and
verify the following conditions.
verify the following conditions.
a. The pump is not started simultaneously with lifting of the nozzle.
b. Replacing the nozzle in the holster stops the pump. Additionally, the nozzle cannot be placed
b. Replacing the nozzle in the holster stops the pump. Additionally, the nozzle cannot be placed
in the holster in a manner that leaves the pump energized.
c. The nozzle can be locked with the use of an ordinary ¼ in. padlock.
3. To preserve battery life hose modules are “locked” before shipping from the E.J. Ward factory. To
unlock the module, rub a strong magnet on the side marked by the “ MAGNETIC UNLOCK ”
indication on the U.L label (Figure 4.)
indication on the U.L label (Figure 4.)
Figure 4 – Unlocking Module
Figure 3 - Right Side Mount
Figure 3 - Left Side Mount
Figure 3 - Top Side Mount