Section 4 : Electrical Interface 
 
 
2015_2000007248-V1 - Draft 
This document and the information therein are the property of Morpho. They must not be 
copied or communicated to a third party without the prior written authorization of Morpho 
31 
June 2015 
 
 
Power Supply 
POE  and  external  power  supply  can  be  used  simultaneously,  but  when  both  power 
supplies are available, priority is given to external power supply. If the external power 
supply fails or is shut down, the terminal will go off and then restart using POE. 
External Power supply 
 
Figure 10: Power supply wiring 
Red 
Power Supply 12-24V DC 
In 
Positive 12-24 Volts, power supply 
Black 
Power ground 
In 
Ground power supply 
 
External power supply 
 
Must comply with IEC 60950-1 standard. 
 
12V to 24V Dc (regulated and filtered) 1 Amp min at 12V.  
 
Could be provided by a 12 Volts Wiegand power supply, which complies with the 
Security Industry Association's Wiegand standard March 1995. 
 
If sharing power between devices, each unit must receive 1A (e.g. two units would 
require a 12vDC, 2A supply) 
 
POE (Power Over Ethernet) 
MorphoAccess®  SIGMA  Lite  Series  terminal's  power  supply  can  also  be  provided  by 
the  Ethernet  using  RJ45  connection  (Power  Over  Ethernet  mode  -  IEEE802.3af  or 
IEEE802.3at type 1 compliant).