Section 4 : Electrical Interface 
 
 
2015_2000007248-V1 - Draft 
This document and the information therein are the property of Morpho. They must not be 
copied or communicated to a third party without the prior written authorization of Morpho 
45 
June 2015 
 
 
Wi-Fi
™ dongle installation 
Wi-Fi™  dongle  shall  be  preferably  installed  outside  the  product  (separate  area  shall 
be reserved in the wall) and connected to the internal USB Mini B (at the rear of the 
terminal) using Morpho cable provided in the kit.  
Wi-Fi™ dongle shall not be exposed to temperature exceeding 50°C (don’t forget  to 
count the thermal dissipation of the product and of the Wi-Fi™ dongle). 
Wi-Fi™ feature requires the product to be powered from an external DC 12V to 24V 
power supply (the POE doesn’t provides enough power for both the terminal and the 
Wi-Fi™ dongle) 
Only  Wi-Fi™  dongle  delivered  by  Morpho  (kit  reference  XXX-TBD)  may  be  installed 
with the terminal for WLAN (Wireless Local Area Network) operation. 
Cable  has  to  be  plugged  on  the upward  USB  connector  of the  rear  panel,  as  on the 
following image: 
 
 
 
Figure 23: Wi-Fi™ dongle installation 
 
 
Wi-Fi
™ 
USB 
dongle 
USB 
extension 
cord