“Sharpness” and as necessary. 
4.  Adjust the ”Device Settings” including “Device Name” and “Timestamp”.  
• 
Click “Enable OSD” to checkmark the box and activate the function. 
• 
Enter the "Timestamp Label" you have chosen. 
• 
Enter the "Timestamp Location" you have chosen. 
5.  Click on the Submit button to submit the new image setting. 
 
 
Description of function keys: 
Metering Method 
The metering method determines the exposure. Different metering 
methods measure the subject brightness differently. 
Center-weighted:  The metering is weighted at the center and then 
averaged for the entire scene.  
Spot: This is for metering the central part of the entire scene. 
Exposure Mode 
Exposure Mode controls a camera by shutter speed and the lens aperture. 
Auto:
 Automatic exposure mode. The default shutter time is 1/30~1/10000 
(1/25~1/10000) and the maximum gain is 36 dB. 
Indoor: The optimum exposure setting is pre-programmed for the indoor 
environment. The default shutter time is 1/30~1/120 (1/25~1/100) 
and the maximum gain is 36 dB. 
Outdoor: The optimum exposure setting is pre-programmed for the 
outdoor environment. The default shutter time is 1/30~1/750 
(1/25~1/750) and the maximum gain is 36 dB. 
Night: The optimum exposure setting is pre-programmed for the night 
environment. The default shutter time is 1/30~1/750 (1/25~1/500) 
and the maximum gain is 12 dB. 
Moving: The optimum exposure setting is pre-programmed for moving 
subjects. The default shutter time is 1/120~1/1,000 
(1/100~1/1,000) and the maximum gain is 36 dB. 
Low noise: The optimum exposure setting is pre-programmed to reduce 
the noise. The default shutter time is 1/8~1/30 (1/7.5~1/25) and 
the maximum gain is 36 dB. 
Customize 1-3: You can customize an exposure mode by adjusting 
individual parameters like Gain and Shutter. 
Schedule:  In the Schedule mode, you can set the customize schedule. 
Select a schedule and set the time period. You can assign one 
of the exposure modes to be the function mode of the 
Remaining time. Check and press to Save.  
Note: The period of the schedule can’t be set across midnight. For 
example, if you want to set a schedule of Night mode from 
22:00 to 04:00, you have to (1) check a schedule and select the 
Night mode and set the period from 22:00 to 24:00, then (2) 
enable the next schedule and set it to Night mode and set the 
period from 00:00 to 04:00. Remember to click Save to activate. 
Denoise 
Denoise (noise reduction) is the process of removing noise from signals.  
 
31