TCM 300 / 300C / 320 / 320C 
 
Isolation material may brake at temperatures below -15 °C.  
Please take care to fix the antenna cable in case vibrations are expected. 
3.3.2  Mounting 50 Ω antennas 
For mounting the receiver at bad RF locations (e.g. within a metal cabinet), an external 50 
Ω antenna may be connected. The whip antenna must be removed in this case! 
 
TCM 320 / 320C provide soldering pads for an SMA connector, e.g. from Tyco Electronics: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Modification procedure: 
„ 
TCM320: Remove whip antenna and mount SMA connector 
„ 
TCM320C: Remove whip antenna and 12pF capacitor. Then mount SMA connector 
 
 
For 315 MHz modules (TCM 300C and TCM 320C) please note that a full approval 
is needed if modules are used with external antennas. 
 
 
When using the SMA connector pads please make sure no mechanical forces are 
exerted on the 16-pin connector! It is recommended to use a strain relief for that 
purpose. 
50Ω 
GND 
GND 
GND 
GND 
X
 
remove
 
TCM320C: 
X
 remove