Справочник Пользователя для EnOcean GmbH STM300C

Скачать
Страница из 46
USER MANUAL V0.82 
© 2010 EnOcean  |  www.enocean.com 
TCM 300 / 300C / 320 / 320C User Manual V0.82  |  Page 41/43 
 
 
TCM 300 / 300C / 320 / 320C 
A.3  Command telegrams and messages 
A.3.1  ID Range commands 
 
Every TCM 300 supports a unique 32 bit ID and in addition a range of 128 IDs starting at 
an BaseID address. At production, every TCM 300 is programmed with a unique ID and a 
BaseID address. The BaseID number can be read via the serial interface. In order to allow a 
replacement of one unit with another unit (without having to go through the learning pro-
cedure with every receiver), the ID range can be changed via the serial interface. 
The allowed ID range is from 0xFF800000 to 0xFFFFFFFF. 
In order to prevent misuse, this feature can only be used 10 times! 
Please note: The unique ID cannot be changed. 
 
Command (TCT) 
Response (RMT) 
SET_BASEID 
OK, ERR, ERR_IDRANGE 
RD_BASEID 
INF_BASEID 
A.3.2  Receiver sensitivity commands 
 
The receiver sensitivity can be changed by the following commands. In LOW sensitivity 
mode, only transmitters in the vicinity of the module are received. 
 
Command (TCT) 
Response (RMT) 
SET_RX_SENSITIVITY 
OK 
RD_RX_SENSITIVITY 
INF_RX_SENSITIVITY 
A.3.3  Reset command 
 
Command (TCT) 
Response (RMT) 
RESET 
 
A.3.4  SW Version 
 
Command (TCT) 
Response (RMT) 
RD_SW_VER 
INF_SW_VER 
A.3.5  Error messages 
 
Error Messages (RMT) 
ERR 
ERR_TX_IDRANGE 
ERR_IDRANGE 
ERR_SYNTAX