Micro-control as 
Operation and Maintenance Manual for MC-3-series 
Page 6 of 9 
MAN-05-006  
Rev. 
2.1.4  Physical Data 
Physical 
size:- 
 MC-3-5 
 230x175x160mm 
   MC-3-6 
 330x220x200mm 
   MC-3000 
250x158x180mm 
   MC-3000+ 
305x200x190mm 
 
Weight:  
 
2-3 kg    
(The weight will vary with the terminal's equipment.) 
2.2  Battery Charger and Batteries 
The operating time for a fully charged battery is 8 hours. This time will vary depending on the system 
specifications and different operating times may be caused by:- 
•  Lower ambient temperatures. 
•  A worn out battery. 
•  The battery is not fully charged. 
•  If the terminal is equipped with additional displays or lamps. 
 
The rechargeable battery should have a lifetime of approx 1000 charging cycles or 2-3yrs. Lifetime 
will vary according to the usage. 
 
2.2.1  Changing the battery 
•  Put the machine being controlled into a safe position. 
•  Turn the terminal OFF. 
•  Remove the battery and insert a fully charged one. 
•  Turn the terminal ON. 
•  Terminals with two batteries fitted can continue to operate, replace only one battery at a time. 
 
2.2.2  Battery Charger Installation and Use 
•  Install the battery charger in a clean and dry environment with temperature +10°C - +40°C. 
•  Connect the charger to the correct supply voltage. 
•  Insert the battery to be charged. 
•  Wait to see the indication that charging is normal. 
•  Leave the battery in the charger until it is required for use. 
•  Use only the battery charger supplied with the system or a replacement from Micro-control. 
•  Batteries not in constant use should be charged at least once every 2 months. 
2.2.3  Disposing of the batteries 
Batteries are hazardous waste and must not be disposed of with normal rubbish. You should dispose 
of the batteries according to local laws and rules, or return them to Micro-control as. 
2.3 Base unit 
All the MC-3-series base units are produced according to the customer’s specifications, the wiring 
diagram shows how the base unit is connected.  
2.3.1  Installation 
•  The base unit should only be connected by a competent electrician. 
•  Take care that the supply voltage is correct. 
•  Install the base unit considering the ambient temperature and IP rating. Ensure it will not be 
damaged by moving machinery and allow for easy access. 
•  If the installation is subject to harsh vibration use isolating mountings, available from Micro-
control.