Справочник Пользователя для SRT Marine Systems plc 425-0002

Скачать
Страница из 92
Technical Information
Page  68
Table 8  Unused Fields
6.10 Proprietary Sentences
The transceiver outputs no proprietary sentences in normal operation.
6.11 Priority of Sensor Ports
The transceiver automatically assigns a priority scheme to connected
sensors. Data from the highest priority sensor will always be used. Sensor
input priority is for: 
●Position
●COG+SOG
●Heading
●Rate-of-Turn 
The sensor input ports have a priority order as shown in Table 9
RMC
7
8
Date: dd/mm/yy 
Magnetic variation, degrees, E/W 
VBW
1
2
3
7
8
9
10
Longitudinal water speed, knots 
Transverse water speed, knots 
Status: water speed 
Stern transverse water speed, knots 
Status: stern water speed 
Stern transverse ground speed
Status: stern ground speed 
VTG
2
Course over ground, degrees mag-
netic 
Port
Priority (1 = highest)
Sensor 1
1
Sensor 2
2
Sensor 3
3
Sentence
Unused Fields
Description