Installation 
10
 
 
To ground the CPE:   
1.  Insert the washer to the M4x8L screw.   
2.  Attach the screw halfway into the earth ground terminal. 
3.  Insert the grounding cable under the washer. 
4.  Tighten the screw. 
Making the Connections 
 
Connect the Ethernet Cable to the Unit     
Use only 5E 4x2x24# FTP (or above) outdoor shielded patch cables from 
an approved manufacturer. 
1.  Remove the sealing cable gland plug from the gland nut. 
2.  Open the sealing gland nut and remove it. Do not disassemble the 
gland base from the bracket. 
3.  Insert the Cat5 RJ-45 cable into the sealing gland base and connect it 
to the Ethernet port at the bottom of the unit. Make sure that the 
connector is completely inserted and tightened. 
NOTE
 
The total length of the Ethernet cable from the unit to the RJ-45 port on the PoE 
must not exceed 80 meters.
 
4.  Insert the rubber bushing on the cable into the gland base.