 INSTALLATION 
 
AC power supply connection: 
Warning: Turn power off before you connect this device to your power supply. 
Make sure your power supply voltage matches the receiver power supply 
requirements: 120 VAC or 277 VAC. 
 
Attach the power cable to the female Mate N Loc connector located in the housing of the 
2WT-2RA-6A unit. 
 
Load Connection: 
Warning: Make sure the power supply voltage matches the voltage of the load to be 
controlled. Otherwise fire or damage to the device or load may occur and it may 
cause electrical shock. 
A male Mate N Loc connector is located at the end of the cable protruding from the 
2WT-2RA-R6 housing which plugs into the load to be controlled. 
Warning: Make sure the load to be connected does not exceed the relay rating. Otherwise 
fire or damage to the device may occur. Please refer to TECHNICAL DATA for relay 
rating.  
 
OPERATION 
Warning: Make sure your power supply voltage matches the receiver power supply 
requirements: 120 VAC or 277 VAC. Otherwise there is electrical shock hazard.
 
Warning: The load must match the relay rating. Otherwise fire or damage to the receiver 
may occur. 
After the master and slave devices are properly connected to the power supply and load, 
turn the power on. The load attached to the slave device(s) can then be turned on or off 
by the 2WT-2RA-R6 master device. 
 
 
TECHNICAL DATA 
Power Supply: 120 VAC or 277 VAC. 
Antenna: Internal. 
Frequency: 915 MHz 
Operation Temperature:  -20 
o
C to 60 
o
C (-4 
o
F to 140 
o
F) 
Number of relays on receiver: 2 
Each relay rating: 
•  20A resistive load 277 VAC 
•  10A Ballast load 120/277 VA 
Certification: FCC compliance 
 
This device complies with Part 15 of the FCC Rules. If this device is operated in 
compliance with the following requirements, it can be operated without notification and 
free of charge in the area of the United States of America.