Справочник Пользователя для Advanced Card Systems Limited AET62
AET62 Design Specification
Version 1.0
Version 1.0
8-DEC-09
Page 16 of 18
AET62
Data In: Blinking Duration Control
Table 3.0C: Bi-Color LED Blinking Duration Control Format (4 Bytes)
Byte 0
Byte 1
Byte 2
Byte 3
T1 Duration
Initial Blinking State
(Unit = 100ms)
T2 Duration
Toggle Blinking State
(Unit = 100ms)
Number of
repetition
Link to Buzzer
Byte 3: Link to Buzzer. Control the buzzer state during the LED Blinking.
0x00: The buzzer will not turn on
0x01: The buzzer will turn on during the T1 Duration
0x02: The buzzer will turn on during the T2 Duration
0x03: The buzzer will turn on during the T1 and T2 Duration.
Data Out: SW1 SW2. Status Code returned by the reader.
Table 3.0D: Status Code
Results
SW1
SW2
Meaning
Success
90
Current LED State
The operation is completed successfully.
Error
63
00
The operation is failed.
Table 3.0E: Current LED State (1 Byte)
Status
Item
Description
Bit 0
Current Red LED
1 = On; 0 = Off
Bit 1
Current Green LED
1 = On; 0 = Off
Bits 2 – 7
Reserved
Remark:
1. The LED State operation will be performed after the LED Blinking operation is completed.
2. The LED will not be changed if the corresponding LED Mask is not enabled.
3. The LED will not be blinking if the corresponding LED Blinking Mask is not enabled. Also, the
number of repetition must be greater than zero.
4. T1 and T2 duration parameters are used for controlling the duty cycle of LED blinking and Buzzer
Turn-On duration. For example, if T1=1 and T2=1, the duty cycle = 50%. #Duty Cycle = T1 / (T1 +
T2).
T2).
5. To control the buzzer only, just set the P2 “LED State Control” to zero.
6. The make the buzzer operating, the “number of repetition” must greater than zero.
7. To control the LED only, just set the parameter “Link to Buzzer” to zero.
6. The make the buzzer operating, the “number of repetition” must greater than zero.