5. Operation 
 
The BR-3503 is powered on 115Vac 60Hz. The connection to the power line outlet is done using 
a permanently attached power cord. It is interfaced to a Doppler processor unit using a single 
four-wire cable equipped with military connectors.  This cable is used to carry the radar Doppler 
signal to the processing unit and the antenna transmission control signals. You should connect 
your radar cable from this connector to the appropriate radar input on your processing unit. 
 
It is important to note that the BR-3503 does not have a power on switch. Consequently, the unit 
is on as soon as it is connected to the wall AC outlet. The transmitter is controlled by software 
and is switched off when in standby mode. To completely switch the unit off, the power cord 
needs to be disconnected from the wall power outlet.
 
 
 
6. Maintenance 
 
The BR-3503 radar does not require much maintenance. Attention should however be paid to a 
few points: 
 
Keep the connectors clean from dirt and moisture to avoid corrosion and bad connections. 
Now and then wipe the radar enclosure with a soft and dry cloth. 
 
The main fuses are located inside the power supply / amplifier unit. To replace them, refer the 
radar system to qualified personnel.  
 
 
Warning: No operator serviceable parts inside the radar unit. Please refer 
servicing to service qualified personnel 
 
 
 
 
 
 
7. Antenna  Connectors Specification 
 
Connector type: ITT CANNON MS3124E16-8P 
 
Pin Description 
A Not 
Connected 
B Not 
Connected 
C Not 
Connected 
Remote Make for Antenna Transmitter Control (+ 5 Vdc source, 2 kOhm 
output resistance) 
E Make 
Ground 
Doppler Signal + (5 Vpp max.) 
Doppler Signal - (5 Vpp max.) 
H Ground 
 
The remote activation of the transmitter is done by the processor by short circuiting pins D and E 
of the connector. When the antenna interface cable is not connected, the radar unit does not 
transmit.
 
 
 