MC-Series High-Power System 
 
Installation 
998--01 Rev X1 
RadioFrame Networks, Inc. 
CONFIDENTIAL AND PROPRIETARY 45 
 
 
4.3.1  iSC-3s 
Note:  Typically, the iSC-3s are installed by RadioFrame Networks before the MC-Series 
High-Power system is shipped. If you need to install an iSC-3, follow this 
procedure. 
1  While supporting the iSC-3, slide the iSC-3 into the cabinet mounting position. 
2  Mount the iSC-3 in the location shown in Figure 26. If necessary, install side rails in 
the mounting position in the rack. 
3  Secure the iSC-3 to the cabinet mounting rails using the four mounting screws 
provided with the unit. Tighten the screws to 4.5 Nm (40 in-lb). 
4  Connect the RFN-provided ground cable (P/N 820-0609-10; ISC1 to GND BAR) 
between the cabinet ground bar and the grounding lug on the rear of the iSC-3, and 
ensure the connection is tight.  
5  Connect the RFN-provided power cable (P/N 820-0613-50; PDU-CTRL_1 to ISC1) 
between the iSC-3 power and the CTRL circuit breaker on the PDU (CTRL 1 for the 
primary iSC and CTRL 2 for the secondary iSC).  
6  Repeat steps 1 through 4 to mount the secondary iSC-3 (cable labels will show 
ISC2 instead of ISC1). 
7  Connect the two iSC-3s according to Sprint Nextel’s installation procedure. 
8  Refer to Figure 27. Using the RFN-provided coax cable (P/N 111-0001-02; BIC-
ERTM 5 MHz IN to ISC1 REF OUT-1), connect the primary iSC-3 port SITE REF 
OUT 1 [K] to the BIC ERTM port 5 MHz IN [L].  
9  Terminate the two remaining SITE REF OUT ports on the primary iSC-3, and 
terminate all three SITE REF OUT ports on the secondary iSC-3. 
10 Using the RFN-provided coax cable (PN 111-0001-02; BIC-CRTC to iSC1 REF 
OUT-1), connect the primary iSC-3 port 10B2-1 to BIC CRTC port 10Base2 iSC. 
11 Terminate the two remaining iSC-3 10B2 ports on the primary iSC-3, and terminate 
all three 10B2 ports on the secondary iSC-3. 
Note:  Figure 27 does not show all cabling. For complete cabling information, refer to 
Appendix C “High-Power iDEN Microcell Rack Stack-Up, 3-Sector (Default) 
Configuration”.