                              PROFESSIONAL  INSTALLATION  MANUAL  FOR  24 dBi  Antenna 
        SmartBridges  Pte  Ltd  manufactures  wireless OutDoor   units  airBridge  OutDoor  
model  NO: SB 2110  and  airPointPRO  OutDoor  model NO: SB 2510  conforming  to  IEEE 
802.11b  spec  operating  in  ISM  band using  external  antennas. The  24  dBi  antenna  has  to  
installed  only  in  point  to  point  application  and  not  in  point  to  multi  point  application .      
•  The  devices  shall  be  installed  by  professional  installers  only .  It is not  to  be  
installed  by  general  public .  
•  The devices  shall  not be  sold  to general  public  directly .The marketing channels are   
1.  Distributors  who  sell  them  to  Wireless  Internet  Service  Providers  who  are  the  
installers .  
2.  Direct to Wireless Internet Service Providers through WebSales  who are the installers  
•  The  Antenna  shall  be  fixed  in  place  and  connected  to  the  device  by  
professional  installer . The  installer  has  to  set  the  output  power  using  Dial – a – 
Power   utility . The  installer  has  to  key  in  the  Antenna  Gain  and Loss  of  the  
cable (Standard  Cable  is  1 meter  long  LMR 400  with N  male  connectors  at  both  
ends ,loss 0.5 dB ) used  to  connect  the  device  to  the  antenna .  The  software  
utility  computes  and  displays  maximum  power  settable  for  FCC  domain . The  RF  
output  power  can  be  set to  a  maximum  of  +17.47 dBm depending on which 
antenna gain selected. If  the  installer  tries  to  set  a  larger  radiated power  output  a  
Warning  Message  appears  on  the  screen   “ Warning  EIRP  exceeds the  maximum  
specified  limits  for  the  regulatory  domain” . The  installer  has  to  reduce  output  
power  till  the  warning  message  disappears .