Справочник Пользователя для Comba Telecom Ltd. RX4122-B

Скачать
Страница из 54
INSTALLATION GUIDE FOR RX-4122 
 
ENU STATUS : 1-0-1 
Copyright - refer to title page 
Page 44 
 
 
 
 
 
Figure 39: Device sub-band setting-Class B 
Reminder:  
 
 
Make sure the frequency of sub-bands match the actual frequency of filters, or BDA cannot work normally. 
 
If the frequency is within [450MHz,470MHz], the bandwidth between DL Freq Low and DL Freq High can 
be adjusted from 0.2 to 5MHz only. If the frequency is within[ 470,512], the bandwidth between DL Freq 
Low and DL Freq High can be adjusted from 0.2-3MHz. 
 
The frequency edges of two sub bands can be overlap, but they cannot be cross-contained. 
 
NOTE:  Make  sure  the  device  is  connected  with  appropriate  donor  and  service  antennas  before 
proceeding to step 5. 
 
Step 5: Click 
 to enter to Isolation Detection Screen. 
 
 
Figure 40: Commissioning Procedure 
– Isolation Detection 
 
  Click 
 to start Isolation Detecting, then a
 
[Confirm] window will pop-up.