Справочник Пользователя для Comba Telecom Ltd. MBDA-200S
USER MANUAL FOR MBDA-200S
ENU STATUS : 1-0-0
Copyright - refer to title page
Page 47
NOTE: For each RF module, the 3 subband bandwidth setting should not be overlap each other, if yes,
only 1 subband can be turn on, other overlap subband is forbided to switch on by equipment.
only 1 subband can be turn on, other overlap subband is forbided to switch on by equipment.
Step 6: Click
to enter to DL output power setting after finishing subband bandwidths and switchs
setting.
Figure 56: Commissioning Procedure
– DL Output Power Setting Screen
Figure 57: Commissioning Procedure
– DL Output Power Setting
NOTE: For each RF module, the total target output power of all subbands which channel switch is on
must not exceed the nominal downlink output power (27, 30, 33dBm); if yes, Tips window will pop-up
must not exceed the nominal downlink output power (27, 30, 33dBm); if yes, Tips window will pop-up
shown as Figure 59. Finish the output power setting, click
button , go to Finish Screen shown as
Figure 60.