Справочник Пользователя для Opticon Sensors Europe BV H32
Opticon
H - 32
Specifications Manual
10
6. Electrical Specifications
6.1. Electrical Characteristics
(Current measured at 3.7V operating voltage)
Parameter
Typ
Unit
Remarks
Operating voltage
3.4–4.2
V
Lithium-ion battery
Operating current
300
mA
Backlight on, WLAN
connected, 1 scan/minute
Stand-by current
<200
mA
Not scanning, WiFi off,
backlight on.
Sleep current
<4
mA
When the power is OFF
6.2. Main Battery
The main battery is a lithium-ion battery:
• Nominal capacity: 1800 mAh (NP120)
• Nominal voltage: 3.7 V.
• Low voltage: Less than 3.4 V
• Usable time: Approx 4 hours.
• Data hold time (clock and SRAM): 2 hours
• Nominal voltage: 3.7 V.
• Low voltage: Less than 3.4 V
• Usable time: Approx 4 hours.
• Data hold time (clock and SRAM): 2 hours
The backup battery is an 15 mAh secondary battery.
6.3. Operating time
Parameter
Typ
Unit
Remarks
Operating time
4
Hours
Backlight on, WLAN
connected, 1 scan/minute
Stand-by time
6
Hours
Not scanning, WiFi off,
backlight on.
Off time
11
Days
When the power is OFF