Справочник Пользователя для AeroScout ANT4200
AeroScout EX4200 Ultrasound Exciter
Chaining Exciters
15
3. A slave is connected to a subsequent slave in the same manner (from OUT to the
next slave’s IN).
4. In the System Manager, under Exciter Properties, Settings, Mark the check box
Exciter is Slave.The slaves will inherit the master's ID and its LF configurations
aside from the transmission range. The transmission range and ultrasound
settings need to be configured individualy for each Exciter.
aside from the transmission range. The transmission range and ultrasound
settings need to be configured individualy for each Exciter.
Note
Exciter EX4200 chaining is supported by Exciter FW V308 or higher and Engine
4.3 or higher.
4.3 or higher.
Figure 8: Slave configuration in System Manager