AeroScout EX4200 Ultrasound Exciter 
 
Chaining Exciters    
15 
3.  A slave is connected to a subsequent slave in the same manner (from OUT to the 
next slave’s IN). 
4.  In the System Manager, under Exciter Properties, Settings, Mark the check box 
Exciter is Slave.The slaves will inherit the master's ID and its LF configurations 
aside from the transmission range. The transmission range and ultrasound 
settings need to be configured  individualy for each Exciter. 
 
 
Note
 
Exciter EX4200 chaining is supported by Exciter FW V308 or higher and Engine 
4.3 or higher. 
 
Figure 8: Slave configuration in System Manager