Справочник Пользователя для AeroScout TAG1410
T14 Patient and Staff Badges
User Guide
13
Badge Management
Configuring and Updating Badges
T14 Badges must be initially configured using the TMBD application (Tag
Manager Bi-Directional application which is part of the Hardware Manager
application) before use. The TMBD application allows you to activate and
application) before use. The TMBD application allows you to activate and
configure the following badge parameters according to a sites infrastructure
and use case.
and use case.
• Transmission and IP Settings:
Wireless LAN Infrastructure
Network Access Information
MobileView IP Settings
• Badge Configuration:
The badge firmware contains 30 pre-defined configurations. These
configurations define the badge type, beacon rate and ultrasound
infrastructure behavior. Each configuration has a unique ID number
called a “Static Configuration” which cannot be edited. Only 1 (one)
infrastructure behavior. Each configuration has a unique ID number
called a “Static Configuration” which cannot be edited. Only 1 (one)
configuration can be selected and used for the badge.
Once the badges have been initially configured using the TMBD application,
future configurations can then be done wirelessly via MobileView.
The following tables show the available configurations according to the Badge
Firmware. For more information please refer to Bi-directional Tags
Configuration Details document (KB Article 7826).
Configuration Details document (KB Article 7826).
Firmware 1.25.xx
Config ID
Badge Type
Ultrasound Infrastructure
Beacon Rate
123
Patient
Gen1
30sec
124
Patient
Gen1
60sec
125
Patient
Gen1
120sec
126
Patient
Gen1
5min
127
Transported Patient
Gen1
30sec
128
Transported Patient
Gen1
60sec
129
Transported Patient
Gen1
120sec
130
Transported Patient
Gen1
5min
131
Patient
Gen2
30sec
132
Patient
Gen2
60sec