SAG
SAFE-O-TRONIC
Installation
Schulte-Schlagbaum AG
Page 7 of 12
SOT-Manual.DOC
4. Installation
Installing:
The electronic cabinet lock SAFE-O-TRONIC is attached on the inside of a cabinet door
using four screws.
Testing:
After installing, check the function of the SAFE-O-TRONIC using the TestKey.
Applying the reference plate:
Stick the user reference plate only to a flat, grease- and dust-free surface.
Configuring:
Once the installation work is complete and all the locks tested, they are configured using
the SetupKey.
5. Commissioning
5.1. Function testing with the "TestKey"
Lock SAFE-O-TRONIC :
1. Activate SAFE-O-TRONIC (push rotary knob)
2. Hold TestKey directly in front of the rotary knob.
3. When the green LED flashes, turn knob 90
°
.
Unlock the SAFE-O-TRONIC :
1. Activate SAFE-O-TRONIC (push rotary knob)
2 Hold TestKey directly in front of the rotary knob.
3. SAFE-O-TRONIC unlocks itself.
NOTE:
The TestKey is used to test the function of factory-new or non-configured SAFE-O-
TRONIC . Once the SetupKey has been used to configure the SAFE-O-TRONIC for
the system, the SAFE-O-TRONIC can no longer be locked or unlocked using the
TestKey!