Справочник Пользователя для Radwin Ltd. 5XACMOD3C

Скачать
Страница из 122
FinM Deployment Guide
Release 4.5.10
4‐29
Configuring Indoor Synchronization Units (ISUs)
Configuring the Radio Network
Figure 4‐18: TMU ‐ Re‐configuration
3. Click OK. The Configurator will take the parameters associated with the unit of this 
name, and download them to the unit whose IP address appears in the First 
Installation
 window.
It may take about a minute to complete. You will receive one of the completion mes‐
sages described in 
 below.
4.6.3 Configuring Indoor Synchronization Units (ISUs)
Use this procedure to carry out changes in the configuration parameters of the ISUs. This 
includes changing or setting its IP address. 
1.  For a first‐time configuration, connect the ISU’s sync socket to your laptop or to a 
LAN connection. Connect AC power to its power input. See 
 for con‐
nection instructions. 
For a re‐configuration of an ISU already installed in the field, you can rely on your 
network’s connection. 
2. Run the Configurator.
3. From the Main tab, click the Line pull‐down menu and select the line on which the 
ISU is defined (see 
). 
4. From the Download Software pull‐down menu, select the appropriate 
configuration option (see 
page 4‐4
 for a description of these options). 
5. Click Configure Unit. The following window will appear: