Справочник Пользователя для CipherLab Co. Ltd. 1560P

Скачать
Страница из 249
98 
Enter Setup 
1560P Series Barcode Scanner 
User Guide
 
2.6.3 INTER-CHARACTER DELAY 
By  default,  the  inter-character  delay  is  set  to  zero.  Specify  a  value,  ranging  from  0  to 
254  in  units  of  millisecond,  to  match  the  computer  response  time  of  the  keyboard 
interface.  Such  delay  time  is  inserted  between  every  character  being  transmitted.  The 
longer the delay time is, the slower the transmission speed will be. 
Inter-Character 
Delay… (*0~254) 
1) Read the barcode above to specify the inter-character delay.
2) Read the “
Decimal Value
” barcode on page 231 for the desired inter-character delay
(millisecond).
3) Read the “Validate” barcode on the same page to complete this setting.
2.6.4 INTER-FUNCTION DELAY 
By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 
in units of millisecond,  to match the computer response time of the  keyboard interface. 
Such  delay  time  is  inserted  between  every  function  code  (0x01  ~  0x1F)  being 
transmitted. The longer the delay time is, the slower the transmission speed will be. 
Inter-Function 
Delay… (*0~254) 
1) Read the barcode above to specify the inter-function delay.
2) Read  the  “
Decimal  Value
”  barcode  on  page  231  for  the  desired  inter-function  delay
(millisecond).
3) Read the “Validate” barcode on the same page to complete this setting.