Справочник Пользователя для CipherLab Co. Ltd. 1560P

Скачать
Страница из 249
 
 
169
 
Update 
 
Chapter 5
    Defining Output Format
 
5.4 CODE ID 
Up  to  two  characters  for  Code  ID  can  be  configured  for  each  symbology.  To  make  the 
Code ID configuration easier, the scanner provides five pre-defined Code ID sets that you 
can select one and make necessary changes on it. 
 
If  “BT  HID”,  “USB  HID”  or  “Keyboard  Wedge”  is  configured  for  interface, 
Key  Type
 
and 
Key Status
 will then become applicable. You may decide whether or not to apply 
Key Status when “Normal Key” is selected for Key Type.   
 
Key Type 
Key Status 
Scan Code   
Only 1 scan code value is allowed. 
N/A 
Normal Key   
Up  to  2  character  strings  are 
allowed. 
 
Add Shift 
 
Add Left Ctrl 
 
Add Left Alt 
 
Add Right Ctrl 
 
Add Right Alt 
Refer to 
Keyboard Wedge Table
Note:  "]C1" is the Code ID of GS1-128 (EAN-128) barcodes; "]e0" is the default Code ID 
of GS1 DataBar (RSS) barcodes. 
5.4.1 SELECT PRE-DEFINED CODE ID 
 
 
 
Apply Code ID Set 1 
 
 
 
 
Apply Code ID Set 2 
 
 
 
 
Apply Code ID Set 3 
 
 
 
 
Apply Code ID Set 4 
 
 
 
 
Apply Code ID Set 5