Chapter 1
    Understanding the Barcode Scanner
 
1.1.3 POWER ECONOMY VS. WPAN CONNECTION 
Before  the  scanner  can  communicate  with  the  host  computer,  Bluetooth  connection  (or 
WPAN  connection)  needs  to  be  established.  The  scanner’s  power  economy  always 
accommodates itself to the establishment of the WPAN connection. 
The following describes how the scanner carries out power economy before and after the 
establishment of the WPAN connection: 
Before establishing a WPAN connection successfully… 
1. 
The scanner stays active for a specified period of time (2 minutes by default) for the following 
scenarios. The CPU runs at full speed, and the LED blinks blue (On/Off ratio 0.5 s: 0.5 s). 
(a) waiting for a connection request from the host (BT SPP Slave Mode)   
(b) trying to connect to the host (BT HID or BT SPP Master Mode) 
(c) trying to connect to 3656 
2. 
If  the  scanner  fails  to  connect  within  2  minutes,  it  becomes  inactive  to  save  power  for  the 
remaining  period  of  time  (the  specified  “Auto  Power  Off”  value  minus  2  minutes).  The  CPU 
starts to run at low speed, and the LED begins to blink red (On/Off ratio 0.3 s: 2.5 s). 
Pull the trigger to wake up the scanner when it becomes inactive, and the scanner will become 
active again. 
3. 
If it fails to connect again and again, and finally stays inactive until the specified Auto Power 
Off time elapses, the scanner will automatically turn off in order to conserve battery power. 
Pull down the trigger for about 2 seconds to turn it on again. 
Note:  For scenarios (a) and (b) in step 1, you may need to search for the scanner again 
on your computer. 
After establishing a WPAN connection successfully… 
1. 
Once a WPAN connection is established successfully, the scanner will stay active for a specified 
period of time (2 minutes by default) for data transmission. The CPU runs at full speed, and 
the LED blinks blue (On/Off ratio 0.02 s: 3 s). 
2. 
If the scanner stays idle for 2 minutes (default), it will then turn inactive to save power for the 
remaining  period  of  time  (the  specified  “Auto  Power  Off”  value  minus  2  minutes).  The  CPU 
runs at low speed, and the LED is blinking red (On/Off ratio 0.3 s: 2.5 s).   
Pull the trigger to wake up the scanner when it becomes inactive, then the scanner will stay 
active again. 
 
For BT HID or SPP, the scanner automatically shuts down after the configured “Auto Power 
Off”  time  without  the  transition  from  full  CPU  speed  to  low  CPU  speed.  However,  when 
connecting with 3656, the scanner will go through the transition in order to save power. 
3. 
If  the  scanner  first  becomes  idle  and  finally  stays  inactive  until  the  specified Auto  Power  Off 
time is up, the scanner will automatically turn off in order to conserve battery power. You will 
hear three short beeps, tone descending from high to low. 
Pull down the trigger for about 2 seconds to turn it on again.   
 
For BT HID, the scanner resumes the connection with the host upon powering on again, as 
long  as  the  host  application  is  running.  You  will  hear  three  short  beeps,  tone  ascending 
from low to high upon the resumption. If the scanner fails to resume the connection, it will