Справочник Пользователя для CipherLab Co. Ltd. 1560P

Скачать
Страница из 249
72 
Enter Setup 
1560P Series Barcode Scanner 
User Guide
 
2.3.3 ACK/NAK TIMEOUT 
By default, the scanner sends data to the host without waiting for an ACK/NAK response 
before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If 
no  response  within  the  specified  period  of  time,  the  scanner  will  attempt  to  send  the 
same  data  two  more  times.  If  all  three  attempts  fail  without  any  notification,  data  loss 
will occur. 
ACK/NAK Time-out 
after … (*0~99) 
1) Read the barcode above to specify the time interval for the scanner to send data and
wait for a response from the host.
2) Read the “
Decimal Value
” barcode on page 231. For example, read “1” and “0” for the
scanner to automatically shut down after idleness of 1 second.
3) Read the “Validate” barcode on the same page to complete this setting.
ACK/NAK Error Beep 
Enable Error Beep 
*Disable Error Beep
Note:  We  suggest  enabling the error beep  so that you will be notified of such data loss 
and have the scanner re-read data. 
2.3.4 SWITCH BETWEEN MASTER/SLAVE MODE 
After  the  scanner  has  established  a  connection  as  a  SPP  slave  device,  you  may  have  it 
read  the  “Activate  BT  SPP,  Master  Mode”  setup  barcode  to  switch  to  SPP  Master  Mode. 
This will result in easy and reliable re-connection, just like connecting with 3656.