Справочник Пользователя для Inside Secure M2502G

Скачать
Страница из 61
Coupler - Reference manual
RM 10
Version 1.2
TRANSMIT
Use
Transmits data from the coupler to the chip and read back chip response.
This command is the one to use to read and write data in the chip.
Prototyping
"
Command sent : C2h
"
Command type : ISO In / Out
Host
80h
C2h
P1
P2
P3
Data
Coupler
C2h
Chip answer
90h
00h
P1 : Defines the contactless communication protocol
P2 : Chip answer length
P3 : Chip command and data
Parameters
P1: Parameter used for contactless configuration
Bit
7
6
5
4
3
2
1
0
Function
Send 
CRC
Check 
CRC
Send 
signature
ISO 
type
RF protocol 
type
Time out
b7: Send CRC:
1: The coupler automatically sends the CRC (function of the Data bytes) to the
chip. Coupler uses the CRC associated to the choosen protocol (bit 1 & 0)
0: Only P3 data bytes are sent.
b6: Compare CRC:
1: Compares the returned CRC with the expected value calculated by the coupler
(verify the data sent by the chip).
0: CRC is not checked.
b5-b4: Time Out:
The time out value depends of the protocol used (b1 and b0 values).
The time out is the time from the command’s EOF (End Of Frame) to the chip
response SOF (Start of Frame).
Bits 4& 5
Time-out 
 15 693
Time-out 
14 443
00
800 µs
200 µs
01
4 ms
1 ms
10
24 ms
6 ms
11
40 ms
10 m