Справочник Пользователя для ERG Transit Systems MCROEM
Device Product Group
Security Level 3
MCROEM User Manual
DPG-00604
ERG Confidential © ERG 2005
Page 10 of 20
Revision 1.0 / 11 October 2005
3.3 Power
Supply
The MCROEM module derives power directly from the host. After supply power is applied to
the MCR it will be operational in less than 1.2 seconds.
the MCR it will be operational in less than 1.2 seconds.
Item
Description
Supply voltage
12Vdc +10%/-5%, with ripple of less than 50mV peak-peak.
Supply current
Maximum 300 mA, typical 150 mA
Input power
requirements
requirements
Maximum 3.60 Watts
3.4 RF
controller
The standards supported by the RF controller are ISO/IEC 14443 Type A, ISO/IEC 14443
Type B and Mifare Standard.
Type B and Mifare Standard.
3.4.1 Transmitter
The MCR transmitter complies with the following specifications:
Item
Description
Carrier Frequency
13.56 MHz + 7 kHz (ISO/IEC 14443-2:2001, 6.1)
Modulation Rise and
Fall Time
Fall Time
< 2.0
µ
sec (ISO/IEC 14443-2:2001, 8.1.2 and 9.1.2)
ASK Modulation
100% Modified Miller (ISO/IEC 14443-2:2001, 7 and 8)
8%-14% NRZ (ISO/IEC 14443-2:2001, 7 and 9)
3.4.2 Receiver
The MCR receiver complies with the following specifications:
Item
Description
Carrier Frequency
13.56 MHz
Subcarrier
Frequency
Frequency
847.5 kHz (ISO/IEC 14443-2:2001, 7, 8 and 9)
Subcarrier Data
OOK Manchester (ISO/IEC 14443-3:2001 7 and 8)
BPSK NRZ-L (ISO/IEC 14443-2:2001, 7 and 9)
3.4.3
Card Interface
The MCR module supports contact-less smart cards conforming to the following signal
interface protocols:
interface protocols:
•
ISO/IEC 14443 Type A.
•
ISO/IEC 14443 Type B.