Справочник Пользователя для ERG Transit Systems MCROEM

Скачать
Страница из 21
Device Product Group 
Security Level 3 
MCROEM User Manual
 
DPG-00604 
ERG Confidential © ERG 2005 
Page 10 of 20 
Revision 1.0 / 11 October 2005 
 
3.3 Power 
Supply 
The MCROEM module derives power directly from the host. After supply power is applied to 
the MCR it will be operational in less than 1.2 seconds. 
Item 
Description 
Supply voltage 
12Vdc +10%/-5%, with ripple of less than 50mV peak-peak.  
Supply current 
Maximum 300 mA, typical 150 mA 
Input power 
requirements 
Maximum 3.60 Watts 
3.4 RF 
controller 
The standards supported by the RF controller are ISO/IEC 14443 Type A, ISO/IEC 14443 
Type B and Mifare Standard. 
3.4.1 Transmitter 
The MCR transmitter complies with the following specifications:  
Item 
Description 
Carrier Frequency 
13.56 MHz + 7 kHz (ISO/IEC 14443-2:2001, 6.1) 
Modulation Rise and 
Fall Time 
< 2.0 
µ
sec (ISO/IEC 14443-2:2001, 8.1.2 and 9.1.2) 
ASK Modulation 
100% Modified Miller (ISO/IEC 14443-2:2001, 7 and 8) 
8%-14% NRZ (ISO/IEC 14443-2:2001, 7 and 9) 
3.4.2 Receiver 
The MCR receiver complies with the following specifications: 
Item 
Description 
Carrier Frequency  
13.56 MHz  
Subcarrier 
Frequency 
847.5 kHz (ISO/IEC 14443-2:2001, 7, 8 and 9) 
Subcarrier Data 
OOK Manchester (ISO/IEC 14443-3:2001 7 and 8) 
BPSK NRZ-L (ISO/IEC 14443-2:2001, 7 and 9) 
 
3.4.3 
Card Interface  
The MCR module supports contact-less smart cards conforming to the following signal 
interface protocols: 
 
ISO/IEC 14443 Type A. 
 
ISO/IEC 14443 Type B.