4  Using the Evaluation Software 
 
4.1  Setting Register Values. 
On both the Volatile and Non-Volatile pages, the registers are labeled by function. To set a register value, 
select the value from the options available for that register and click the “Write” button. To perform a read 
of that register, simply click the “Read” button. Descriptions of the register functions can be found in the 
Wi.232FHSS Users Manual. 
 
4.2  Diagnostic Mode Commands 
There are a special class of commands available through the evaluation software.  These controls are 
accessed by clicking the “Show” button in the “Diagnostic Window” group located on the “Volatile 
Registers” page as seen below. 
 
 
These commands place the module into special diagnostic modes that can be used to test the module’s 
performance, or to activate the transmitter for RF testing purposes.  
NOTE:  once a module executes a 
diagnostic command, it should be reset or have the power cycled to return to normal operation.
 
 
4.2.1 Transmit 
Diagnostic 
Transmit Diagnostic consists of the controls located in the “Transmit Diagnostic” group.  The transmit 
diagnostic group is broken into two smaller sub-groups. 
The left side is used to observe static transmitter characteristics- that is, when the “TX 1-Channel Diag” 
button is clicked, it stops the module from hopping frequencies.  The radio buttons on the left allow quick 
selection of the transmitter’s channel/frequency.  Once activated, a “…1010101010101…” bit pattern is 
transmitted for bit error testing or RF carrier analysis.  This single-channel transmit diagnostic mode can 
be used with the receive diagnostic. 
The right side is used to observe dynamic transmitter characteristics.  Dynamic transmitter operation 
allows the module to hop frequencies as it transmits.  The “Hop Set” radio button selects the hop 
sequence (analogous to a channel, values are 0-5) to be used when hopping.  Dynamic transmitter mode 
cannot be used to provide a carrier for the Receive Diagnostic.  Clicking the “Tx FHSS Diag” button sends 
the new hopping sequence value to the module and activates the transmitter.  The “Start Hop” and “Stop 
Hop” buttons start and stop the diagnostic hopping, respectively. 
In the middle, the light-orange colored box controls the power and modulation characteristics of the 
transmitter.  For the FCC-Wi.232FHSS-25
™, there are four power settings of increasing intensity: Low, 
Mid-Low, Mid-High, and High.  The “Mod Off” and “Mod On” buttons switch the carrier’s modulation off 
and on, respectively.