Connecting the Power Cable (MST2HAC)
The MST2HAC versions need an outdoor rated power cable to connect to a compatible AC power source.
AC power source specifications (at MST200 interface): 100-240Vac, 100W
The MST2HAC product offering offers two ways to connect the unit to AC power. Two power cord variants 
are offered and a connector kit that allows the customer to assemble their own cable if the standard 
offering does not meet deployment needs.
The applicable SKUs for these options are:
The difference between the NA and INTL part variants is the color coding of the conductors. 
The North American cable uses Black (Hot), White (Neutral), and Green (Ground). 
The INTL part follows the international schema of Brown (Hot), Blue (Neutral) and Yellow/Green 
(Ground)
Best Practice for Outdoor Connection to AC Mains
In all circumstances and with any outdoor infrastructure the recommended practice is to connect to AC 
mains in an order grade weather protected junction box. This needs to be implemented by a qualified 
resource in a manner that is consistent with the electrical code in force in the jurisdiction of deployment. In 
many countries this will require a licensed electrician to perform this operation.
In Japan, this would is a Certified Electrician by Ministry of Economy, Trade and Industry.
The use of plugs with infrastructure equipment is suitable only for temporary installs where nuisance 
tripping of GFI plugs is considered tolerable. Should it be desired to attach a plug to the cable assemblies 
then the installer is expected to follow all directions provided with the plug end in a fashion consistent with 
local electrical code.
Use of the CKIT-OD-AC-P
Assembly instructions for this part are shipped with the part. All instructions must be followed to ensure 
proper assembly of the connector onto the cable.
The required specifications for third party cable used with the CKIT solution are as follows:
AC power cable specifications (when using AC connector kit and custom cable): minimum voltage/
current rating 250V/1A, diameter 6-12mm, rated for outdoor use and UV exposure
!
Installation and service of Aruba Networks products should be performed by Professional Installers.
The MST200 does not ship with any power cables; these are available as accessories and should be ordered 
separately. 
Table 6  SKUs for Powering Options
Part Number
Description
PC-OD-AC-P-NA
Weatherproof AC power cable(5m), North America version
PC-OD-AC-P-INT
Weatherproof AC power cable(5m), International (EU) version
CKIT-OD-AC-P
Weatherproof connector kit for AC power interface