The ETD BOLUS
 is sealed in an inert polypropylene capsule and weighted to prevent 
the bolus from being expelled from the rumen or from being passed through the digestive 
system. Powered by a sealed lithium battery, the ETD BOLUS
 has a functional lifespan 
– without attention – of approximately five years. 
Because a cow’s normal temperature can vary according to the temperature of their 
environment, the ETD BOLUS
 monitors and calculates a ‘normal reference’ 
temperature for each animal, adjusting this reference temperature according to seasonal 
and climatic changes.  
In addition to long-term health monitoring, the ETD BOLUS
 can also be used for 
veterinarian monitoring to report reactions to injections, implants or other treatments and 
can be used for ovulation monitoring (in development) to report when an animal is ready 
for artificial (or natural) insemination following the use of fertility stimulants. 
NOTICE TO THE USER 
Any changes or modifications not expressly approved by CowTek, Inc for compliance 
could void your authority to use the equipment. 
FCC WARNING 
This device complies with part 15 of the FCC rules. Operation is subject to the following 
two conditions: (1) this device may not cause harmful interference, and (2) this device 
must accept any interference received, including interference that may cause undesired 
operation. 
Desktop Exciter 
The Desktop Exciter is used to ‘turn on’ a pill before it is given to the cow or bull.   
Because of FCC requirements for active transmitter devices and to ensure 
maximum battery life (estimated ~5 years), the HeathWatch
 temperature 
pills are shipped in a 
QUIET
 or 
OFF
 mode and must be initialized before 
use. 
The Desktop Exciter – see Figure 2 – has a recessed grove on the top shaped to the 
orientation of the pill; three mode buttons labeled 
WAKEUP
FERTILITY
 and 
VETERINARY
 
and three threshold buttons labeled 
WINTER
NORMAL
 and 
SUMMER
.  In addition there are 
two LEDs – one 
RED
 and one 
GREEN
 – which show operation and status; one serial port 
(DB9, RS232, not shown); and a power connection (not shown).