Справочник Пользователя для Redline Communications Inc. AN100UXA

Скачать
Страница из 136
 
 
 
User
 
 
AN-100U/UX Base Station
 
Manual
 
 
 
70-00058-01-04 
Proprietary Redline Communications © 2010  
Page 28 of 136 
April 19, 2010 
AN-100UX 
AN-100UX  Power  supply  options  include  single  AC  or  DC  types.  Cables  are  included 
with AC and DC power  supplies. Backup  power  can be supplied only from a  +48 VDC 
power supply. 
Table 8 - IDU Installation - RedMAX AN-100UX Power Specifications 
 
Voltage range 
[V] 
Tolerance 
[%] 
Power 
consumption 
max. [W] 
Max. 
Current 
[A] 
Inrush 
current 
1
 
[A] 
Main AC Input 
2
 
100 - 240 VAC 
10% 
120 
100 
Main DC Input 
48 - 60 VDC 
20% 
120 
70 
Backup. DC Input 
+48 VDC 
5% 
120 
30 
1. Typical Inrush current is less then 500 us. DC: measured, AC: P/S manufacturers data. 
2. Auto-sensing. 
 
IMPORTANT: DC Polarity 
The AN-100UX backup power supply is DC type and must be connected using 
positive polarity: the +48 VDC must be connected to +Ve input on the AN-100UX. 
Refer to Installation Guidelines for additional details.
 
 
 
3.1.3  Wireless Section 
This section describes the wireless port, time synchronization ports, and wireless LEDs. 
 
 
Figure 9: System - AN-100U/UX Front Panel Wireless Section 
IF Port (Radio Control) 
A  female  N-type  port  provides  connection  via  a  coaxial  cable.  This  port  provides  the 
following functions: 
-  Local oscillator signal for synchronization between the terminal and radio 
-  Telemetry signals for control and monitoring the modem 
-  IF modulated data to/from the radio (wireless interface) 
-  DC power to the transceiver (see following table) 
 
 
Table 9: System - AN-100U/UXIF Cable Voltage  
AN-100U 
24 VDC 
AN-100UX 
48 VDC 
Time Synchronization Port 
The  synchronization  interface  has  two  SMA  female  connectors  located  on  the  front 
panel. Refer to section for additional information. When operating two or more collocated 
base stations (BSs), transmitter operations MUST use synchronization to minimize inter-
sector  interference.  Refer  to  the  RedMAX  Base  Station  Installation  Guidelines  for 
complete details.