1. Press the MODE Button until the 
Error Lamp
 twinkles 5 times. 
2. Change the mode and option using the MODE Button according to the MODE   
z
 MODE button : use for changing OPTION status. (
Error Lamp
z
 FEED button : use for changing MODE status.      (
Power Lamp
Ex) The defaults of the printer are : UART/ 9600 bps/ 8 data bit / No parity 
/ 1 Stop bit / Density Low 
            If a user wants to modify the defaults with Bluetooth / 57600 bps / 7 data 
bit / Odd parity / 2 Stop bit / density high   
 
Press MODE Button until 
Error Lamp
 twinkles 5 times and release the 
button. 
             
→ You will see the 
Power Lamp
 twinkles one time and the 
Error Lamp
 
twinkles 1 time. 
             
→ Press the MODE Button 2 time and the 
Error Lamp
 twinkles 3 times. 
                    (The interface mode has set to Bluetooth mode) 
 
Press FEED button one time, 
Power Lamp
 twinkles twice and 
Error Lamp
   
twinkles 1 time. 
             
→ Press the MODE Button 3 times and the 
Error Lamp
 twinkles 4 times. 
          (The baud rate has set to 57,600 bps) 
     
Press FEED Button one time, 
Power Lamp
 twinkles 3 times and 
Error Lamp
 
twinkles 2 times. 
             
→ Press MODE Button one time, 
Error Lamp
 twinkles one time. 
          (The Data Bit has set to 7 data bit)