5  SSI OPENWAY 2.0 Display Feature 
 
 
Note:   These display codes are only visible when the SmartSynch Option Board type is selected 
in the meter program and the option board fields are enabled. 
 
1. SmartSynch Identifier:  In general, the meter program controls the number of displays, associated 
fields, and display time.  This 3-letter field identifies SmartSynch display among available displays.   
Note:  This is a user defined field and can be changed by the customer. 
 
Values 
Description 
SSI 
SmartSynch, Inc. 
 
2. SmartMeter Warning: displays error codes generated by SmartSynch embedded software. 
 
 
 
Normal operations – no errors 
 
SmartMeter module’s NVRAM error 
 
Read/write failure in the Common Configuration area - NVRAM 
 
Read/write failure in the App. Specific Configuration area - NVRAM 
 
Actual firmware binary image is corrupted 
 
Firmware image decompression error 
 
Meter clock deviation is greater than the maximum correction limit 
 
Software watchdog triggered – processor is reset 
 Good.  
 Warning.  
Error
  
 
 
3. Wireless Coverage Status: coverage status detected by the GPRS modem. 
 
Values 
Description 
In coverage: modem can hear the network 
Out of coverage: modem can’t hear the network